Function
This command is used to read the current setting of the
channel warnings mask applied to signal observations. This
mask is active only when applying masks to signal
observations has been set to be user defined (see
$PASHS,SOM).
Command Format
Syntax
$PASHQ,SOM,WRN[*cc]
Parameters
None.
Response Format
Syntax
$PASHR,SOM,WRN,s1,s2*cc
Parameters
Parameter
Description
Range Default
d1
Mask applied to differential data, in dBHz
0-60
28
d2
Mask applied to raw data, in dBHz
0-60
28
*cc
Checksum
*00-*FF
Parameter
Description
Range
Default
s1
Mask applied to differential data
ON, OFF ON
s2
Mask applied to raw data
ON, OFF OFF