COMMAND DETAILS
103
:TRIGger:PULSe:TIMe
Description
Sets or queries the pulse width time.
Syntax
:TRIGger:PULSe:TIMe {<NRf> | ?}
Related
commands
:TRIGger:TYPe
:TRIGger:PULSe:WHEn
Parameter
<NRf>
Pulse width time (4ns~10s)
Return parameter <NR3>
Returns the pulse width time in
seconds.
Example
:TRIGger:PULSe:TIMe 4.00E-5
Sets the trigger pulse width to 40.0us.