Ref<x>:timebase:scale, Ref<x>:offset – GW Instek GDS-200 Series Programming Manual User Manual

Page 88

Advertising
background image

GDS-200 & GDS-300 Programming Manual

88

Parameter

<X>

Reference waveform 1, 2

<NRf>

Horizontal co-ordinates

Return parameter <NR3> Returns the reference waveform position

Example

:REF1:TIMebase:POSition -5.000E-5
Selects reference 1, and then sets the horizontal
position to -50us.

:REF<X>:TIMebase:SCALe

Description

Sets or returns the selected reference waveform
time base scale.

Syntax

:REF<X>:TIMebase:SCALe { <NRf> | ?}

Related
commands

:REF<X>:DISPlay

Parameter

<X>

Reference waveform 1, 2

<NRf>

Horizontal scale

Return parameter <NR3> Returns the reference waveform scale.

Example

:REF1:TIMebase:SCALe 5.00E-4
Selects reference 1, and then sets the horizontal
scale to 500us/div.

:REF<X>:OFFSet

Description

Sets or returns the selected reference waveform
vertical position (offset).

Syntax

:REF<X>:OFFSet { <NRf> | ?}

Related
commands

:REF<X>:DISPlay

Parameter

<X>

Reference waveform 1, 2

<NRf>

Vertical offset

Return parameter <NR3>

Returns the reference waveform vertical
position.

Set

Query

Set

Query