COMMAND DETAILS

69

Example

:MEASure:SOURce1 CH1
:MEASure:FPReshoot?
Selects Channel 1, and then measures the fall
preshoot.

:MEASure:FREQuency

Description

Returns the frequency value.

Syntax

:MEASure:FREQuency?

Related
Commands

:MEASure:SOURce<X>

Return parameter <NR3>

Returns the frequency in Hz.

Chan Off

Indicates the source channel is not
activated.

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:FREQuency?
1.0E+3
Selects Channel 1, and then measures the
frequency.

:MEASure:PERiod

Description

Returns the period.

Syntax

:MEASure:PERiod?

Related
Commands

:MEASure:SOURce<X>

Return parameter <NR3>

Returns the period.

Chan Off

Indicates the source channel is not
activated.