2.3 Primary Input/Output Display and Controls

Figure 3 describes the primary input/output display and controls in detail.

Figure 3 - Primary Input/Output Display and Controls

Item

Name

Description

1

Display

A 2 line, 16 character, display providing all visual user
feedback for the primary output and input operations.See
section 2.6 for layout details, and section 2.7 for possible
error messages.

2

Numeric and secondary

Output value data entry keys.Secondary function selection

function keys

per the text printed above the numeric key. Press the

key followed by the numeric key to select the func-

tion.

OUTPUT

Change RTD/Ohms or Thermocouple to output mode.

INPUT

Change RTD/Ohms or Thermocouple to input mode.

ZERO

Zero the input for Pressure, Thermocouple millivolts, or
RTD ohms

SETUP

Adjust the LCD Contrast, LCD Backlight, and Remote
Interface Configuration as described in section 8.

CJC

Select internal or external cold junction compensation for
Thermocouple temperature measurements. When external
compensation is selected, XCJC is displayed at the start of
the second line.

°C/°F

Select Centigrade or Fahrenheit units for RTD and
Thermocouple temperature measurements.