NOTE: Plastic cover must be reattached to maintain
hazardous location rating.

3. Strip the cable jacket back 2 inches (50mm).
4. Strip the 4 wires back ¼ inch (6mm).
5. Thread wires through the proper cable access.

Connect the wires to the compression style screw
terminals of the Detector Junction Box.

RED

SHIELD

CLEAR

SHIELD

18 AWG

OR 1mm2

BELDEN 9155 OR EQUIVALENT

BELDEN 8770
OR
EQUIVALENT

18/20 AWG

OR 1.0 / 0.5 mm 2

20 AWG

18 AWG

20 AWG

18 AWG

FOR ZONE 1 INSTALLATION

CONDUIT SEAL LOCATED AT
ENCLOSURE ENTRY PER 505.18

SEAL

FOR CLASS 1 DIV 1 OR 2 FOLLOW
NEC 501.4 AND 501.5.
FOR CLASS 1 ZONE 1 FOLLOW
NEC. 505.15 AND 505.18

EP

E2

SHLD

SHLD

E1

SHLD C2 C1

+5V

-5V

EP

E2

SHLD

SHLD

E1

WHITE
BLACK

GREEN

RED

+5V

-5V

ELECTRODE WIRES

Red to terminal labeled -

E1

Green to terminal labeled -

SHLD

Black to terminal labeled -

E2

White to terminal labeled -

EP

Cable length, between Junction Boxes, may be up to 100
feet (30M).

6. Run cable and conduit to Amplifi er junction box.

Electrode Wiring in Amplifi er Junction Box
To connect the electrode wires in the Amplifi er Junction Box:
1. Unscrew the amplifi er junction box chamber cover. If

necessary, use a strap wrench.

2. Remove the protective plastic cover to access the

terminal block screws.

NOTE: Plastic cover must be reattached when wiring is
complete to maintain hazardous location rating.

3. Strip the cable jacket back 2 inches (50mm).
4. Strip the 4 wires back ¼ inch (6mm).
5. Thread wires through the proper cable access. Connect

the wires to the compression style screw terminals of the
Amplifi er Junction Box.

SHIELD

RED
GREEN
BLACK
WHITE

BELDEN 9155 OR EQUIVALENT

SHIELD

BELDEN 8770
OR
EQUIVALENT

RED
CLEAR

SEAL

SHIELD

RED

CLEAR

FOLLOW NEC 504

BLACK

WHITE

GREEN

PINK

C1 C2 SHLD

E1

SHLD

+5V

E1

SHLD

E2

EP

SHLD

-5V

+5V

-5V

EP

E2

SHLD

CONDUIT SEAL LOCATED AT
ENCLOSURE ENTRY PER 505.18

FOR ZONE 1 INSTALLATIONS

ELECTRODE WIRES

Red to terminal labeled -

E1

Green to terminal labeled -

SHLD

Black to terminal labeled -

E2

White to terminal labeled -

EP

Coil Wiring in Detector Chamber
To connect coil wires in the Detector chamber:
1. Lay out the cable and conduit between the Detector

Junction Box and the Amplifi er Junction Box. Use Belden
#8770 cable or equivalent for coils.

NOTE: Plastic cover must be reattached to maintain
hazardous location rating.

2. Strip the cable jacket back 2 inches (50mm).
3. Strip the 2 wires back ¼ inch (6mm).
4. Thread wires through the proper cable access. Connect

the wires to the compression style screw terminals of the
detector chamber.

RED

SHIELD

CLEAR

SHIELD

18 AWG

OR 1mm2

BELDEN 9155 OR EQUIVALENT

BELDEN 8770
OR
EQUIVALENT

18/20 AWG

OR 1.0 / 0.5 mm 2

20 AWG

18 AWG

20 AWG

18 AWG

FOR ZONE 1 INSTALLATION

CONDUIT SEAL LOCATED AT
ENCLOSURE ENTRY PER 505.18

SEAL

FOR CLASS 1 DIV 1 OR 2 FOLLOW
NEC 501.4 AND 501.5.
FOR CLASS 1 ZONE 1 FOLLOW
NEC. 505.15 AND 505.18

EP

E2

SHLD

SHLD

E1

SHLD C2 C1

+5V

-5V

EP

E2

SHLD

SHLD

E1

WHITE
BLACK

GREEN

RED

+5V

-5V

COIL WIRES

Red to terminal labeled –

C1

Clear to terminal labeled –

C2

5. Connect conduit to junction box. Use a NEMA 4X ½ inch

NPT fi tting.

6. Install protective plastic cover over terminal blocks.
7. Attach detector chamber cover.

Cable length between Junction Boxes may be up to 100 feet
(30M).