Detector specifications, Est. weight, Specifications – Badger Meter M-Series M4000 User Manual

Page 28: With amplifi er

Advertising
background image

28

DETECTOR SPECIFICATIONS

SPECIFICATIONS

Flow Range: 0.1 to 39.4 ft/s (0.03 – 12 m/s)
Flow Direction: Uni-directional or Bi-directional
Sizes: 1/4" to 12" (6 to 300mm)
Conductivity: Min. 5 micromhos/cm
Accuracy: ± 0.25% of rate for velocities greater than 1.64 ft/s (0.50 m/s)

± 0.004 ft/s (± 0.001) m/s) for velocities less than

1.64 ft/s (0.50 m/s)

Electrode Materials: Alloy C, 316 stainless steel, gold/platinum plated,
tantalum, platinum/rhodium
Liner Material: PFA from 1/4” to 3/8" (6 to 10mm), PTFE from 1/2" to
12" (15 to 300mm), soft and hard rubber from 1" to 12" (25 to 300mm)
NSF Listed:

Models with hard rubberl liner, 4-inch and up

PTFE liner - all sizes

Fluid Temperature:
With remote mounted amplifi er

PFA, PTFE: -4°F to 248°F (-20°C to 120°C) @ Max.

ambient temp. of 122°F (50°C)

Soft & Hard rubber: 32°F to 178°F (0°C to 80°C)

@ Max. ambient temp. of 122°F (50°C)

With meter mounted amplifi er

PFA, PTFE: -4°F to 212°F (-20°C to 100°C) @Max.

ambient temp. of 122°F (50°C)

Soft & hard rubber: 32°F to 178°F (0°C to 80°C)

@ Max. ambient temp. of 122°F (50°C)
Pressure Limits: Max. 150 psi (10 bar)
Ambient Temperature: -20°F to 122°F (-29°C to 50°C)
Coil Power: Pulsed DC
Pipe Spool Material: 316 stainless steel
Spool Housing Material: Carbon steel, welded - NEMA 4 (IP66)
Junction Enclosure Material: (for remote mounted amplifi er option)
Cast aluminum (powder coated paint), NEMA 4X (IP66)
Flanges: Carbon steel or 316 stainless steel (ANSI B16.5 Class 150 RF)
Grounding Rings (optional, 2 required) : 316 stainless steel
Meter Size

Thickness (one ring)

1/4" to 10" (6 to 250mm)

.135" (3.43mm)

10" to 12" (250 to 300mm)

.187" (4.75mm)

Grounding Electrode (optional): Alloy C, 316 stainless steel, gold/plati-
num plated, tantalum, or platinum/rhodium
Electrical Classifi cation: FM approved for Class I, Div 1 Groups C-D,
Class II, Div 1 Groups E, F & G - CSA Certifi ed
Pressure Limits: Max. 150 psi (10 bar)
Ambient Temperature: -4ºF to 122ºF (320ºC to 50ºC)
Locations: Indoor and outdoor
Altitude: Maximum 6500 feet (2000m)

Flow Range

Size

A

B

C

D

with Amplifi er

GPM

LPM

inch

mm inch mm inch mm

inch mm inch mm Lbs Kg Min Max Min Max

¼ 6

6.7

170 14.45 366 3.5 89 15.15 388 12.5 5.7 0.02 5 0.063 20

5

/

16

8

6.7

170 14.45 366 3.5 89 15.15 388 12.5 5.7 0.03 9 0.114 34

3

/

8

10

6.7 170 14.45 366 3.5 89 15.15 388 12.5 5.7 0.05 14 0.177 53

½ 15 6.7

170 14.45 366 3.5 89 15.15 388

12.5 5.7 0.11 33 0.416

125

¾ 20 6.7

170 14.65 371 3.9 99 15.25 393 15.5 7.0 0.2 59 0.75 225

1 25 8.9

225 14.85 376 4.3 108 15.45 398 22.0 10.0 0.3 93 1.20 350

1¼ 32

8.9

225 15.65 396 4.6 117 16.25 418 24.0 10.9 0.5 152 2.00 575

1½ 40

8.9

225 15.85 400 5.0 127 16.45 422 25.0 11.4 0.8 239 3.00 900

2 50

8.9

225 16.35 413 6.0 152 16.95 435 29.5 13.4 1

373 4.70 1400

2½ 65

11.0 280 17.55 444 7.0 178 18.15 466 42.0 19.0 2

631

8 2400

3 80

11.0 280 17.85 450 7.5 191 18.45 472 43.6 19.8 3

956 12 3600

4 100 11.0 280 18.85 476 9.0 229 19.45 498 54.1 24.6 5 1493 19 5600
5 125 15.8 400 20.05 508 10.0 254 20.65 530 80.0 36.4 8 2334 30 8800
6 150 15.8 400 21.05 534 11.0 279 21.65 556 83.2 37.8 11 3361 40 12700
8 200

15.8

400

22.95

582

13.5

343

24.15

618

127.6

58.0

20

5975

75

22600

10 250 19.7 500 27.25 691 16.0 406 27.85 713 162.4 73.8 30 9336 120 35300
12 300 19.7 500 29.35 744 19.0 483 29.95 766 250 113.6 45 13444 170 50800

Est. Weight

M-4000 Meter Mount Amplifi er on Detector

M-4000 Remote Mount Junction Box on Detector

7.42"
188mm

B

A

Ø C

9.20"
234mm

5.47"
139mm

3.73"
95mm

7.64"
194mm

SIZE

SIZE

8.35"
212mm

7.22"
183mm

14.52
368mm

5.20"
132mm

7.52"
191mm

7.52"
191mm

5.20"
132mm

7.22"
183mm

B

A

Ø C

3.54"
90mm

4.25"
108mm

9.20"
234mm

5.47"
139mm

3.73"
95mm

SIZE

Advertising