Amplifier specifications – Badger Meter M-Series M4000 User Manual

Page 29

Advertising
background image

29

SPECIFICATIONS

Power Supply: 85-265VAC, 45-65Hz
Power Consumption: 20W
Accuracy: ± 0.25% of rate for velocities greater than
1.64 ft/s (0.50 m/s)

± 0.004 ft/s (± 0.001 m/s) for velocities less

than 1.64 ft/s (0.50 m/s)
Repeatability: 0.1% of rate
Flow Range: 0.10 to 39.4 ft/s (0.03 to 12 m/s)
Fluid Conductivity: Min. 5.0 micromhos/cm
Flow Direction: Unidirectional or bidirectional
(programmable)
Totalization: 3 separate displayable totalizers – 10

digits (programmable - forward, reverse and net)

Analog Outputs: 0-10mA, 0-20mA, 4-20mA

(programmable and scalable)

Voltage sourced (18VDC) – isolated

Max. loop resistance = 750 Ω

Frequency Output: Open Collector – Max. full scale

fl ow = 10Khz

Digital Outputs:

(2) Open collector, (programmable – scaled

pulse, fl ow alarm, status, or frequency output)

Max. 24VDC, 0.5W

(2) AC solid state relay (programmable – fl ow

alarm or status). Max. [email protected]
Pulse Width: Open collector, 5ms to 1 second

(programmable) or automatic 50% duty cycle

Min-Max Flow Alarm: Open collector or solid state

relay (programmable – 0 to 100% of fl ow)

Empty Pipe Detection: Field tunable for optimum
performance based on specifi c application
Excitation Frequency: Programmable - 3.75Hz, 7.5Hz
or

15Hz

Auxiliary Input: Max. 24VDC (programmable – positive

zero return, external totalizer reset or preset

batch start)
Noise Dampening: 1 to 30 seconds (programmable)
Units of Measure: U.S. gallons, imperial gallons, million

gallons per day, cubic feet, cubic meters, liters,

oil barrels, pounds, ounces, acre feet
Low Flow Cut-Off: 0 to 100% of full scale

(programmable)
Zero-Point Stability: Automatic correction
LC Display: 4 lines X 16 character alphanumeric – back

light, actively displays 3 totalizer values, fl ow

rate, alarm status, output status, error / diagnostic

messages
Programming: Internal 3 button or external magnetic
wand
Galvanic Separation: £ 500 volts
Electrical Classifi cation:

FM approved for Class I, Div I, Groups B-D

Class II, Div 2, Groups E, F and G - CSA Certifi ed

Housing: Amplifi er enclosure and remote junction

enclosure: cast aluminum (powder coated paint)

Housing Rating: Amplifi er enclosure and remote

junction enclosure – NEMA 4X (IP66)

Mounting: Direct detector mount or remote wall mount –

bracket included. (for remote mount, max. cable

distance = 100 ft (30M)

Field Wiring Entry Ports: (3) ½ “ NPT, internal thread
Ambient Temperature: -20°F to 122°F (-29°C to 50°C)
Communication: RS232C serial, standard ANSI terminal

compatible data stream

AMPLIFIER SPECIFICATIONS