Badger Meter M-Series M4000 User Manual

Page 26

Advertising
background image

26

• The screen goes back to DIG OUTPUT 1 33.

4. Pres + six times, or - once to Select Function.

5.When Select Function is selected, screen Z1 appears for

two seconds.

6. It then switches to SELECT OUT #1 3J. Make a selection.

Press E.

7. This type of screen shows for two seconds and then

returns to DIG OUTPUT 1 33.

Whichever selection is made from screen SELECT OUT #1 3J,
the next screen always shows XXXXX ** SELECTED**.

The screen then returns to DIG OUTPUT 1 33 where you will

have to:

1.

Select

Functions

screen

2.

Screen

Z1

appears

3.

Select

another

screen.

Do this until all required select Out #1 35 are

programmed.

There are four Digital Outputs in this program. Perform the
same for all of them, if applicable. (Note that not all output
functions are available on all outputs.)

Analog Output

1. Press E once to move cursor to Main Menu.

2. In the MAIN MENU 00, press + three times to move the

cursor to Inputs/Outputs. Next, press E.

3. At IN/OUTPUTS 30 press + once to place the cursor at

Analog Output. Press E.

4. In ANALOG OUTPUT 31 press + once to move the

cursor to Range Select. Press E.

5. In RANGE SELECT 3A select a range with the + button

and then press E.

6. The screen returns to ANALOG OUTPUT 31. Press + twice

to move the cursor to Zero Calibrate and then press E.

Connect amp meter to mA analog output pins 5 and 6.

7. In ANALOG ZERO 3B make a selection of Decrease or

Increase based on what the amp meter is reading.