4-17-5 getstoragearray (subtarget=component), Section – HP XP Command View Advanced Edition Software User Manual

Page 102

Advertising
background image




Command line interface commands



102

Command execution result:

RESPONSE:

An instance of StorageArray

.

. (Attributes of StorageArray are omitted here)

.

List of 1 CommParameters elements:

An instance of CommParameters

userID=root

ipAddress=172.16.45.1

4-4-17-5 GetStorageArray (subtarget=Component)

GetStorageArray (subtarget=Component)

obtains information about the configuration of

one or all storage subsystems (see parameters in

Table 4-35

).

A user to whom a user-defined resource group is assigned can obtain information about the
configuration storage subsystems that the user is permitted to access.

Table 4-35

GetStorageArray (subtarget=Component) command parameters

Parameter Name Status

Description

model

Optional

Model of the storage subsystem
If you omit this parameter, you will obtain information about the models of
all storage subsystems.

serialnum

Optional

Serial number of the storage subsystem
If you omit this parameter, all the storage subsystems become the target.

subtarget

Required

Specify Component.

Command execution example: In this example, the CLI command obtains information about the
configuration of a storage subsystem (serial number: 10011, model: XP512).

hdvmcli GetStorageArray -o "D:\logs\XP512 GetStorageArray_Component.log"
subtarget=Component model=XP512 serialnum=10011

Command result:

RESPONSE:

An instance of StorageArray

objectID=*****

name= [email protected]

description= XP512 (10011) at 10.208.114.140

serialNumber=10011

arrayFamily=XP512/48

arrayType=XP512

microcodeVersion=01-13-56/00

agentVersion=02-01-06/00

productName=XP512

controllerVersion=01-18-01-00/00

numberOfControllers=1

capacityInGB=1,329

cacheInMB=7,168

sharedMemoryInMB=-1

numberOfSpareDrives=-1

freeCapacityInGB=338

allocatedCapacityInGB=990