4-24 refreshstoragearrays, Table 4-57 refreshstoragearrays command parameters, Y y y – HP XP Command View Advanced Edition Software User Manual

Page 158

Advertising
background image




Command line interface commands



158

thpType=0

consumedCapacityInKB=0

thpPoolID=0

threshold=15

tcaPoolID=-1

*****

: The value is encoded by the CLI.

4-4-24 RefreshStorageArrays

RefreshStorageArrays

refreshes the configuration information of all storage subsystems by

performing a re-discovery operation on each storage subsystem that is managed by the Device
Manager.

For storage subsystems that are managed by the Device Manager, configuration information that is
created or modified from the Remote Console, Remote Web Console, or XP RAID Manager is
added to or updated in the Device Manager server database each time the
RefreshStorageArrays

command is executed. To keep the Device Manager server database

current, you should run the RefreshStorageArrays command and include the desired interval
parameter (see

Table 4-57

).

NOTE:

To refresh only one storage subsystem, use the AddStorageArray command. When the

storage array already exists, the AddStorageArray command performs a re-discovery operation
on the storage subsystem and refreshes the registered information on the Device Manager server
database.

A user to whom a user-defined resource group is assigned, and who has only View permission
cannot execute this command.

Table 4-57

RefreshStorageArrays command parameters

Parameter Name Status

Description

interval

Optional

Interval time in minutes from storage subsystem re-discovery completion
to start of next storage subsystem re-discovery
You can specify a value from 0 to 2147483647. If it is not set, the default
interval time is 0.
An error is generated if you specify a negative number or if you include the
plus (+) sign.

This command is designed to refresh configuration data for all discovered storage arrays managed
by the Device Manager. Any storage array reconfigurations made by tools other than the Device
Manager (for example, Remote Web Console) are applied in the Device Manager Configuration
database.

If storage arrays are managed by the Device Manager and other tools, you should schedule
RefreshStorageArray

periodically so that the Device Manager Configuration database is kept

current.

Command execution example:

hdvmcli RefreshStorageArrays -o "D:\logs\RefreshStorageArrays.log"
"interval=1440"

Command execution result:

RESPONSE:

[An instance of StorageArray

.

. (Attributes of StorageArray are omitted here)

Advertising