5-2 addlunscan, Table 4-59 addlunscan command parameters – HP XP Command View Advanced Edition Software User Manual

Page 161

Advertising
background image




Command line interface commands



161

realCapacityInKB=0

percentUsed=0

numberOfLUNs=0

*****

: The value is encoded by the CLI.

Command execution example 2:

hdvmcli AddLogicalGroup -o "D:\logs\AddLogicalGroup.log" "groupname=toro"
"iconfile=group12.gif" "parent=*****"

*****

: The value is encoded by the CLI.

Command execution result 2:

RESPONSE:

An instance of LogicalGroup

objectID=*****

name=toro

logicalPath=root/toro

parentID=*****

icon=group12.gif

capacity=0

capacityInKB=0

realCapacityInKB=0

percentUsed=0

numberOfLUNs=0

*****

: The values are encoded by the CLI.

4-5-2 AddLunScan

AddLunScan

detects LUNs not allocated to logical groups on a storage subsystem, and allocates

them to a logical group (see

Table 4-59

). It assigns those LUNs to subgroups of the "LUN Scan"

group according to port and security. AddLunScan creates those subgroups, as necessary,
returning the specified storage array and each of the previously unassigned LUNs.

A user to whom a user-defined resource group is assigned and who has only View permission
cannot execute this command.

NOTE:

HP recommends that you execute this command in a configuration where the number of

paths is less than 65536.

Table 4-59

AddLunScan command parameters

Parameter Name Status

Description

serialnum

Required

Serial number of the storage array to scan

model

Required

Model of the storage array to scan

Command execution example:

hdvmcli AddLunScan -o "D:\logs\XP1024 AddLunScan.log" "serialnum=10001"
"model=XP1024"

Command execution result:

RESPONSE:

An instance of StorageArray

.

. (Attributes of StorageArray are omitted here)

.

Advertising