Snmp alerts and settings – HP Remote Insight Lights-Out Edition II Board User Manual

Page 31

Advertising
background image

Using the RILOE II 31

Parameter Default

value

Definition

Level of Data
Returned

Medium

This parameter configures how much data is returned to
Insight Manager.

None returns no data.

Low returns the current board status and the board type
(RILOE II).

Medium returns the board status, the board type, and the
serial number.

High returns the board status, the board type, the serial
number and several other pieces of information.

View XML Reply

N/A

This parameter displays the XML reply sent to Insight
Manager. This parameter only displays when you use
Internet Explorer.

SNMP alerts and settings

In the Administration>SNMP Settings section, you can enable, disable, and test SNMP alerts. SNMP
alerts are forwarded from the host server and RILOE II to an Insight Manager console. The two types of
alerts are:

Host OS Generated SNMP Traps—The Insight Management agents provided for each
supported network operating system generate these alerts. These agents must be installed on the host
server to receive these alerts. Alerts are sent to Insight Manager clients on the network and
forwarded asynchronously by RILOE II to users that have been configured to receive them.

Remote Insight Board Alerts—These alerts are generated when RILOE II detects conditions that
are independent of the host server operating system. These alerts can be Insight Manager SNMP
traps or pager alerts. Alerts include major events, such as a host server power outage or host server
reset, and RILOE II events, such as a disconnected keyboard cable or an unauthorized login attempt.

To enable alerts: