Calibrating Moisture

Ag Leader Technology

(Harvest Mode)

September 2003

3-9

Important Notes

• You must calibrate the monitor for grain moisture, for each grain type

before the monitor can accurately measure grain moisture.

• Make sure the temperature has been properly calibrated before

calibrating moisture.

• You do not have to calibrate for grain moisture at the beginning of the

season to get accurate results, although it is recommended. Once
calibrated, the monitor will automatically correct all grain moistures for
all the loads that were previously harvested of that grain.

Actual Moisture

To calibrate moisture, you must obtain the actual moisture for one specific
monitor load of the grain you want to calibrate.

Ideally, a moisture calibration load should be one, to two combine hoppers
in size where the grain varies little in moisture content.

Use a reference moisture sensor and take readings from several grain
samples from the load.

CAUTION: To prevent death or serious injury to you or others do
NOT enter the grain tank when the separator is running.

NOTE: Make sure the moisture sensor does not have a buildup of sticky
material on it (this can be a problem with soybeans) when you are
harvesting the moisture calibration load. You will know there is buildup if
your moisture is reading 8-10 or more percentage points too high.

Moisture

To view the moisture calibration screen press the:

Calibration

Screen

MENU key

CAL key
MOISTURE key