Problem

Cause

Solution

Incorrect Temperature
Reading

Temperature offset had
been set to a large
negative or positive
number.

Press MENU, DIAG and YEILD to display
temperature calibration number (Temperature
Offset). If this number is not between –15% to
+15% calibrate temperature and recheck
moisture calibration.

Cable connections are
bad.

Disconnect cab, distribution and moisture sensor
cables and inspect pins for corrosion. Inspect
the cables for cuts or pinches. Reconnect cables
and check temperature again.

Area count switch is in
down position.

Area count switch must be up to make AREA
ON appear on the screen.

AREA OFF Always
Displayed
NOTE: The
AREA ON must be
displayed to count
acres.

Stop height number is
set too high.

Press MENU, CAL, STOP HGT and ENTER
HEIGHT to display stop height setting. Adjust
stop height so that when the head is raised
AREA OFF appears on the screen. NOTE: Stop
height settings can be different for different
grain types
.

Header sensor installed
backwards.

Refer to Installation Instruction. Ensure header
sensor is installed in the correct place with the
correct orientation (cable toward the rear of
combine, open end of black header sensor
bracket pointing towards ground).

Cable connections are
bad.

Disconnect cab, distribution and moisture sensor
cables and inspect pins for corrosion. Inspect
the cables for cuts or pinches. Reconnect cables
and check temperature again.

Header sensor bad.

Check resistance of the header sensor between
pins, A, B, and C on header sensor cable. Refer
to Reference Section for correct resistance
readings.

Monitor Chirps While
Harvesting

Monitor is set on a
partial swath.

Display SWATH on the screen. Use the up/down
arrow keys to adjust to a full swath.

A continuous Field
Marker key is on

Press MENU, OPTIONS, and MARKS, find the
marker that is flashing and press the key below
that mark.

Advertising