Checking Data Accuracy

PFadvantage

End of Season

Ag Leader Technology

September 2003

4-48


Before You Begin

After harvest season ends, remove the monitor from the combine cab. Use
the provided 12-volt power supply to turn on the monitor in your house or
shop and check the recorded yield data for errors. Options for checking the
data follow:

• If you are using the GPS receiver and memory cards, print the season

summary using mapping software that will read yld files from the
memory card.


• If you cannot print a summary, follow the instructions on these pages

and use the monitor to check your data for accuracy.

Calibration

Any load for which you see an error listed in the % Err column of the
summary is a calibration load. Check the following:

• Actual weight and grain type of each calibration load, ensuring that the

loads are set correctly


• Load with a large error in the % Err column, which is any load with an

error 5% or higher. Most loads should be 1% to 4% error.


• Loads with unusually large errors may need to turn off the loads as

calibration loads by pressing the CAL ON/OFF key.

Refer to the Grain Weight document in the Calibration section for
instructions on examining and correcting any errors.

If you do not have a summary print out, follow these steps to check the
calibration errors on the monitor:

Step

Action

1

Press the Menu Key, CAL, WEIGHT, select the grain type and press
SHOW CAL LOADS.

2

On the Grain Calibration screen for the selected grain type press
PERFORM CAL.