Festo Кабели и принадлежности User Manual

Page 102

Advertising
background image

A. Technical appendix

A−14

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

Read digital nominal value M10

Command Message, WRC = 18

d

/ 19

d

Byte

Function

Contents for signed 32 bit

Contents for float 32 bit

Byte 0

Control byte

LOAD = 1 (see section 5.2.3)

Byte 1

Subindex

Not relevant

Byte 2

Command Message
type

X=18

d

, Y=50

d,

Z=82

d

, U=114

d

X=19

d

, Y=51

d

, Z=83

d

, U=115

d

Byte 3

Response Message
type

0 (no update permitted)

Byte 4

Cmd. Data 1

Not relevant

Byte 5

Cmd. Data 2

Byte 6

Cmd. Data 3

Byte 7

Cmd. Data 4

Response Message

Byte

Function

Contents for signed 32 bit

Contents for float 32 bit

Byte 0

Status byte

LOAD COMPLETED = 1 (see section 5.2.3)

Byte 1

*)

Byte 2

Fault code

See fault treatment in section 6.5

Byte 3

RMT

Copy from byte 2 of the Command Message

Byte 4

Resp. Data 1

Position value

9999990

9999990 Ģm

**)

Position value

9999 990

9999 990 mm

**)

Byte 5

Resp. Data 2

−9999990 ... +9999990 Ģm

**)

−9999.990 ... +9999.990 mm

**)

Byte 6

Resp. Data 3

Byte 7

Resp. Data 4

*)

Not relevant

**)

In the event of a fault: extended fault code (see section 6.5)