4. Commissioning

4−7

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

I/O control signals (overview)

A detailed explanation of the I/O control signals can be found
in the system manual for the SPC200.

Record Select mode

Control signal

Address in the
SPC200

Description

ENABLE

I10.0

Controller enable

RESET

I10.1

Reset programs (in conjunction with STOP = 0)

STOP

I10.2

Stop positioning task (0 = stopped)

CLK_A/B

I10.3/I10.4

Start NC record from program A/B

RECBIT1...10

I11.0, I11.1,
I11.8 ... I11.15

Bits for NC record number:
RECBIT1 for 2

0

etc. (record bit)

READY

Q10.0

System ready to operate

ACK_A/B

Q10.1/Q10.2

Task accepted for program A/B (acknowledge)

RC_A/B

Q10.3/Q10.4

NC record concluded by program A/B (record complete)

Start/Stop mode

Control signal

Address in the
SPC200

Description

ENABLE

I10.0

Controller enable (1 = controller enabled)

START/RESET

I10.1

Start/Continue or reset programs
(RESET in conjunction with STOP = 0)

STOP

I10.2

Stop program sequence (0 = stopped)

SYNC_IA/IB

I10.3/I10.4

Synchronization input for M00

READY

Q10.0

System ready to operate

SYNC_OA/OB

Q10.1/Q10.2

Synchronization output for M00

MC_A/B

Q10.3/Q10.4

MC output for program A/B (motion complete)

Tab. 4/1:

Control signals