6. Diagnostic and error treatment

6−7

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

6.4

Diagnosing the SPC200 via the field bus

The 8−figure hexadecimal fault messages of the SPC200 can
be transmitted in the form of 4 I−Bytes or 2 input words
(each 16 bits) via the bit Strobed I/O Message Connection
(seeĂsectionĂ4.2.3).

Downloading via the POLL connection is also possible (see
section 5.2.3, last item: command Read fault message").

Composition of the diagnostic information

The two input words or diagnostic words contain the 8−figure
fault number of the SPC200. This fault message can also be
inspected with the control panel or with WinPISA. The coded
fault message contains information on:

ć

the fault class

ć

the axis identifier

ć

the fault number

ć

if applicable, additional information.

A detailed description of the possible fault messages can be
found in the SPC200 manual.