1. System summary

1−7

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

1.5

I/O address ranges and assignments (mapping)

The following table shows the address assignment in the
SPC200 when a field bus module is used:

Module

Max. address range

1)

I0.0 ... I0.9

1)

Q0.0 ... Q0.7

1)

I/O module on the first axis
interface string

I1.0 ... I1.15

Q1.0 ... Q1.15

First I/O module

I2.0 ... I2.9

Q2.0 ... Q2.7

I/O module on the second
axis interface string

I3.0 ... I3.15

Q3.0 ... Q3.15

Second I/O module

I4.0 ... I4.9

Q4.0 ... Q4.7

Third I/O module

I5.0 ... I5.9

Q5.0 ... Q5.7

Field bus module

I10.0 ... I13.15

Q10.0 ... Q13.15

1)

Address range is not available if a field bus module is used

If a field bus module is used, maximum 3 I/O modules may
be inserted. These provide only freely programmable I/Os in
the operating mode Start/Stop.