2 devicenet profiles: i/o assignment and functions, Devicenet profiles: i/o assignment and functions – Festo Кабели и принадлежности User Manual

Page 64

Advertising
background image

5. Data structure

5−6

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

5.2

DeviceNet profiles: I/O assignment and functions

The DeviceNet profile consists of 8 bytes for writing and
8Ăbytes for reading the desired data into/out of the SPC200.
The basic composition of the communication telegram:

Byte

0

1

2

3

4

5

6

7

Command
Message

Control
byte

Sub−index

Command
Message
type

Response
Message
type

Command Data

Response
Message

Status
byte

Fault code

Response
Message
type

Response Data

The Command Message is generated by the user and conĆ
tains commands for writing or reading data. The Response
Message is returned by the SPC200 to the PLC and contains
the data or a fault code if the SPC200 cannot process the
commands.

There are three groups of commands:

Control commands

These commands start

ć

a program (Start/Stop mode) or

ć

an NC record (Record Select mode).

} section 5.2.1

Update commands

These commands read

ć

the actual positions of the axis or

ć

the field bus outputs of the SPC200 (Q10...13).

} section 5.2.2

Parameter commands

These commands write or read parameters
(e.g. position register or flag).

} section 5.2.3