Festo Кабели и принадлежности User Manual

Page 96

Advertising
background image

A. Technical appendix

A−8

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

Write digital nominal value M10 (only with Start/Stop)

Command Message, WRC = 3

d

/ 4

d

Byte

Function

Contents for signed 32 bit Contents for float 32 bit

Byte 0

Control byte

LOAD = 1 (see section 5.2.3)

Byte 1

Subindex

Not relevant

Byte 2

Command Message type

X=3

d

, Y=35

d

, Z=67

d

, U=99

d

X=4

d

, Y=36

d

, Z=68

d

, U=100

d

Byte 3

Response Message type

0 (no update permitted)

Byte 4

Cmd. Data 1

Position value

9999990

9999990 Ģm

Position value

9999 990

9999 990 mm

Byte 5

Cmd. Data 2

−9999990 .. +9999990 Ģm

−9999.990 ... +9999.990 mm
When written the values are

d d

fi

f

Byte 6

Cmd. Data 3

rounded to two figures after
the decimal point.

Byte 7

Cmd. Data 4

the decimal point.

Response Message

Byte

Function

Contents

Byte 0

Status byte

LOAD COMPLETED = 1 (see section 5.2.3)

Byte 1

*)

Byte 2

Fault code

See fault treatment in section 6.5

Byte 3

RMT

Copy from byte 2 of the Command Message

Byte 4

Resp. Data 1

*)

or extended fault code (see section 6.5)

Byte 5

Resp. Data 2

*)

Byte 6

Resp. Data 3

*)

Byte 7

Resp. Data 4

*)

*)

Not relevant

Advertising
This manual is related to the following products: