5. Data structure

5−7

Festo P.BE−SPC200−COM−CANDN−EN en 0511a

5.2.1

Control commands

Byte 0 in the Command Message controls with its bits all
necessary control signals of the SPC200. These are explained
in detail in chapter 5 of the system manual. See also Tab. 4/1
in this manual.

Start/StopĂmode

Command Message

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

SYNC_IB

SYNC_IA

STOP

START/
RESET

ENABLE

1 ... 7

With a rising edge at input START (bit 1 of byte 0) the
program created in the SPC200 is started (or continued).

Response Message

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

MC_B

MC_A

SYNC_OB

SYNC_OA

READY

1 ... 7