A.1 technical data – Festo Электроцилиндр User Manual

Page 105

Advertising
background image

6

Diagnostics

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

105

6.4.4

Other problems and remedies

Problem

Cause and remedy

Controller does not

work at all

•

Check all cables and connections for short circuit, disconnections or

incorrect pin allocation.

•

Observe the information in the assembly instructions for the cables and

plugs used.

•

Blown internal fuse: Internal short circuit, completely replace the

controller.

Controller does not

achieve the specified

performance data

•

Incorrect control signals from master controller (incorrect signals,

incorrect level). Observe the timing diagrams in the Commissioning

chapter.

•

Incorrect controller setting. Observe the information in the online help

section of the FCT plug-in for the correct settings of the controller

parameters.

•

Error in the power supply. Observe the tolerance values in accordance

with the chapter “Technical data”.

Tab. 6.4

Other problems and remedies