A.1 technical data – Festo Электроцилиндр User Manual
Page 105

6
Diagnostics
Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English
105
6.4.4
Other problems and remedies
Problem
Cause and remedy
Controller does not
work at all
•
Check all cables and connections for short circuit, disconnections or
incorrect pin allocation.
•
Observe the information in the assembly instructions for the cables and
plugs used.
•
Blown internal fuse: Internal short circuit, completely replace the
controller.
Controller does not
achieve the specified
performance data
•
Incorrect control signals from master controller (incorrect signals,
incorrect level). Observe the timing diagrams in the Commissioning
chapter.
•
Incorrect controller setting. Observe the information in the online help
section of the FCT plug-in for the correct settings of the controller
parameters.
•
Error in the power supply. Observe the tolerance values in accordance
with the chapter “Technical data”.
Tab. 6.4
Other problems and remedies