2 speed mode (binary profile only) – Festo Электроцилиндр User Manual

Page 78

Advertising
background image

5

Commissioning

78

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Target recognition (Motion complete/MC)

The drive behaves differently during target recognition, depending on whether the end speed = 0 or <> 0

has been parameterised:

End speed = 0

A position record with a specified end speed = 0 is considered complete when the following two con-

ditions are fulfilled:

–

The actual position is located in the target position window (identical for all records, see FCT,

“Messages” panel).

–

The first condition has at least been fulfilled over the specified time period (“MC damping time”,

identical for all positioning records, see FCT, “Messages” panel).

Behaviour after target recognition:

–

In

closed-loop operation: As long as no other drive function is executed, the drive will stop at the

target position in a position-controlled manner. Standstill monitoring is activated in the binary

profile.

–

In

open-loop operation: As long as no other drive function is executed, the drive will stop at the

target position with the parameterised holding force.

End speed <> 0 (for record linking only)

A position record with a specified end speed <> 0 is considered complete when the target position has

been reached or exceeded.

Behaviour after target recognition:

The drive continues to run with the end speed of the position record in a speed-controlled manner. The

speed is not monitored (speed regulation, but no monitoring of the deviation). The force is limited to

the maximum value defined in the position record.

Advertising