121
Condition for status transition
Description
18
Error
Operation enabled
The cause of the fault must be eliminated
(e.g. over-temperature reduced to permissible value).
Positive edge for CW.
FR (Error Reset)
CW.
PSOn (output stage on after Error reset) = 1
CW.
EO (Enable Operation) = 1
CW.
QS (Quick Stop) = 1
CW.
EV (Enable Voltage) = 1
CW.
SO (Switch on) = 1
19
Error
Switched on
The cause of the fault must be eliminated
(e.g. over-temperature reduced to permissible value).
Positive edge for
FR (Error Reset)
CW.
PSOn (output stage on after Error Reset) = 1
CW.
EO (Enable Operation) = 0
CW.
EV (Enable Voltage) = 1
CW.
SO (Switch on) = 1
Tab. B.8
Description of transitions
Control word (CVE object #2)
Bit
Abbreviation
Description
0
CW.SO
Switch on
1
CW.EV
Enable voltage
2
CW.QS
Quick stop
3
CW.EO
Enable operation
4
CW.ST
Start
5
Must always be 0.
6
CW.PSOn
Power stage on after reset
(Output stage on after error reset)
7
CW.FR
Error reset
8
CW.STP
STOP
9 … 31
Must always be 0.
Tab. B.9
Control word