Festo Электроцилиндр User Manual

Page 99

Advertising
background image

6

Diagnostics

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

99

Table of error messages

31h

CVE connection

Can be parameterised as:

E/-/-

Diagnostic memory: optional

A connection error has occurred during "Control via Ethernet" (CVE).

•

Check the connection: plug disconnected, cable lengths observed, shielded cable used, screening

connected?

–

Acknowledgement option: Error can only be acknowledged after eliminating the cause.

Parameterisable error response(s):

B, C, D, E, F, G

32h

FCT connection with master control

Can be parameterised as:

E/-/-

Diagnostic memory: optional

Connection to the FCT has been interrupted.

•

Check the connection and perform a reset if necessary.

–

For parameterisation as an error: The error can only be acknowledged after eliminating the cause.

Parameterisable error response(s):

B, C, D, E, F, G

33h

Output stage temperature warning

Can be parameterised as: -/

W/I

Diagnostic memory: optional

Temperature of output stage increased.

•

Check cylinder sizing.

•

Check motor and cabling for short circuits.

•

Check the mechanics for sluggishness.

•

Reduce the ambient temperature, improve heat dissipation.

–

For parameterisation as a warning: The warning disappears if the temperature is back below the

danger threshold.

34h

Save Torque Off (STO)

Can be parameterised as:

E/W/I

Diagnostic memory: optional

The “Safe Torque Off” safety function has been requested.

•

Please observe the separate documentation for the STO function.

–

For parameterisation as an error: The error can be acknowledged.

Parameterisable error response(s): 0

–

For parameterisation as a warning: The warning disappears if the STO is no longer requested.

37h

Standstill monitoring

Can be parameterised as: -/

W/I

Diagnostic memory: optional

The actual position is outside the downtime window. Parameterisation of the window may be too

narrow.

•

Check parameterisation of the downtime window.

–

For parameterisation as a warning: The warning disappears if the actual position is within the

standstill window again or a new record has been started

.