4 creating a parameter backup file – Festo Электроцилиндр User Manual

Page 50

Advertising
background image

5

Commissioning

50

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Through the digital output “Force limit reached” (DOUT 11), reaching the parameterised

maximum force (“Torque”) can be displayed. In this way, with corresponding para-

meterisation, a load limit can be displayed at which the motor can no longer follow the

position sequence (following error). An additional following error message is not activ-

ated with these parameter records.

14.Click the <Download> button underneath the position record table in order to transfer the new

position records to the CMMO-ST.

15.

To test the taught position records: click the <Move to Pos.> button next to the desired position

record. The drive moves to the respective position.

Fig. 5.13 Executing position records

16.To permanently

store the new position records in the CMMO-ST: remove the check mark next to

“Control Enable” and then click the <Store> button underneath the position record table.

Fig. 5.14 Saving position records in the CMMO-ST

5.3.4

Creating a parameter backup file

When parameterisation is complete you can create a backup copy of your parameters by using the web

browser. If you ever need to replace the CMMO-ST, you can import this parameter file into the new

CMMO-ST. Re-parameterisation is therefore no longer required.

1. Establish a connection to the CMMO-ST and launch your web browser as described in section 5.2.5.

2. Click <Upload parameter set to PC>.

Fig. 5.15 Creating a backup copy

3. Click <Save> in the Windows dialogue window “Download file” to save the file to your computer. Give

the file a unique name (*.fpf = Festo Parameter File).

4. To import the parameter backup file into a new CMMO-ST: proceed as described in section 5.3.3

under points 4 ... 7.

The backup copy can also be created by using FCT (“Component / Online / Administer

recovery file...”).

Advertising