4 electrical installation, 1 overview, 4electrical installation – Festo Электроцилиндр User Manual

Page 31

Advertising
background image

4

Electrical installation

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

31

4

Electrical installation

4.1

Overview

Caution

Uncontrolled drive motion may cause personal injury and material damage

•

Switch off the

power supplies prior to any assembly, installation or maintenance

work and prevent them from being restarted accidentally.

Caution

Faulty pre-assembled lines may destroy the electronics and trigger unexpected move-

ments of the motor.

•

When wiring the system only use the supplied connectors and preferably the cables

that are listed as accessories (

Tab. 4.1).

•

Lay all flexible lines so that they are free of kinks and free of mechanical stress; if

necessary use chain link trunking.

If unused plug connectors are touched, there is a danger that damage may occur to the

CMMO or to other parts of the system as a result of electrostatic discharge (ESD). Place

protective caps on unused terminals to prevent such discharges.

Note

To ensure compliance with EMC safety:

The maximum length of the individual cables should not exceed 30 m.

The project engineering performance data relates to a maximum cable length of 10 m.

To ensure compliance with the IP protection class (if required):

•

Please note that the specified IP protection class is only achieved with a full plug

and cable assignment.

Advertising