Festo Электроцилиндр User Manual

Page 94

Advertising
background image

6

Diagnostics

94

Festo – GDCP-CMMO-ST-EA-SY-EN – 1301a – English

Table of error messages

14h

Negative direction locked

Can be parameterised as:

E/-/-

Diagnostic memory: optional

A limit switch error or a software limit position error has occurred and subsequently a movement in

the blocked direction has been initiated.

•

Check the target data.

•

Check positioning area.

•

This error can only be acknowledged if the drive is within the valid movement range. If necessary,

start a corresponding position set or move the drive by using the jog function. Movements in a

negative direction are blocked.

–

Acknowledgement option: Error can only be acknowledged after eliminating the cause.

Parameterisable error response(s): A,

B, C, E, F

15h

Output stage temperature exceeded

Can be parameterised as:

E/-/-

Diagnostic memory: optional

The permissible limit value for the output stage temperature has been exceeded. The output stage is

possibly overloaded.

•

This error can only be acknowledged if the temperature is within the permissible range.

•

Check cylinder sizing.

•

Check motor and cabling for short circuits.

•

Check the mechanics for sluggishness.

•

Reduce the ambient temperature, improve heat dissipation.

–

Acknowledgement option: Error can be acknowledged.

Parameterisable error response(s): A, B,

C, D

16h

Output stage temperature too low

Can be parameterised as:

E/-/-

Diagnostic memory: optional

The ambient temperature is below the permissible range.

•

Increase the ambient temperature. This error can only be acknowledged if the temperature is

within the permissible range.

–

Acknowledgement option: Error can be acknowledged.

Parameterisable error response(s): A, B,

C, D

17h

Logic voltage exceeded

Can be parameterised as:

E/-/-

Diagnostic memory: optional

The logic power supply monitor has detected an overvoltage. This is either due to an internal defect

or an excessive supply voltage.

•

Check external supply voltage directly on the device.

•

If the error is still present after a reset has been conducted, it means there is an internal defect

and the device has to be replaced.

–

Acknowledgement option: Error can be acknowledged.

Parameterisable error response(s): A,

B