SECTION 6 - TROUBLESHOOTING

6-32

– JLG Lift –

3121228

Code 38 - Battery Voltage Low - Warning Level 2 - Two (2) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
2, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code. Failure to do so,
will result in a fault code 39.

Code 39 - Battery Voltage Low - Warning Level 3 - One (1) LED/LCDs lit

To maximize battery life, it is recommended that the factory supplied batteries be charged continuously for a minimum of 4
hours or until 8 bars are lit on the ground station LCD Display before operating the machine. When drained to Warning Level
1, batteries must be charged until 8 bars are lit on the ground station LCD display to clear the fault code.

Code 40 - RESERVED

Codes 41 thru 46 - RESERVED

Codes (100 - 199) Ground Control Module - Fault Condition

Check For These Obvious Conditions First:

• That all battery and harness connectors secure and undamaged on Ground Control Module.
• Batteries have sufficient charge.
• Confirm that the static ground strap attached under base frame is secure and undamaged.

Table 6-34. Codes (100 - 199) Ground Control Module - Fault Condition

STEP

ACTION

SPEC

YES

NO

1.

Recycle machine power 5 times allowing a 10 second interval between
each power recycle. Does fault clear?

Done

Go to Step 2

2.

Which code number is displaying?

Code 103

Go to Step 3

Replace

Ground Control

Module

Code 119

Go to Step 5

3.

Confirm that both installed batteries are 12 Volt DC.

12V DC

Go to Step 4

Replace with proper

Batteries

4.

Check battery voltage while charger is operating. Is voltage within specifi-
cation?

Maximum of

31 Volts DC

Replace

Ground Control

Module

Repair or Replace

Battery Charger