SECTION 4 - CONTROL COMPONENTS

4-12

– JLG Lift –

3121228

Service Programming Mode - (Level-2)

In the Service Programming Mode the following items are
shown on the main menu (Also See Table 4-1 on Page 4-
13)
:

• Reset Timers
• Program
• Tilt Sensor
• OSS Sensor

NOTE: There are two production modules available at this

time, one for North/South American and European
languages, and one for Asian languages. All pro-
grammable items between these modules are identi-
cal with the exception of language selection.

Reset Timers

This setting displays five (5) timers as described following:

Trip Time: This timer shows total accumulated hours

since last trip timer reset. This is the hour meter reading
displayed on the Ground Control Module LCD Display
during normal machine operation.

Traction Time: Displays the amount of accumulated

DRIVE hours on the machine’s current drive compo-
nents.

Lift UP Time: Displays the amount of accumulated time

the machine has operated the Lift UP function.

Lift DOWN Time: Displays the amount of accumulated

time machine has operated the Lift DOWN function.

Total Time: Displays the total amount of time accumu-

lated by the Traction, Lift UP and Lift DOWN Timers.

Of these five (5) timers, the Trip Timer is the only timer
which can be RESET back to 00000.0.

Brush Wear Sensor Timer: This timer must be reset

after the drive motor brushes are replaced and the
brush wear sensors are repositioned. When reset the
display will go from WORN to a blank display. Also the
25 hr./10 second countdown will stop and normal
machine operation will resume.

Program

Allows service personnel to program the Level-2 and
Level-3 items shown in Table 4-1 on Page 4-13.

Tilt Sensor

Allows service personnel to reset the Ground Control
Module’s internal digital Tilt Sensor to zero (0.0) degrees
in both the X and Y axis.

ZEROING THE TILT SENSOR REQUIRES THE MACHINE TO BE
RESTING ON A SURFACE CHECKED WITH A DIGITAL LEVEL
MEASURING WITHIN 0.0 DEGREES LEVEL IN BOTH THE X AND Y
AXIS DIRECTIONS.

NOTE: When entering this mode the LCD will display in real

time the current X and Y degree readings of the tilt
sensor. The reading being displayed is based on the
previous zero setting and may not reflect level of the
machines current resting surface.

1. Position the machine on a level surface verified level

in both the X and Y axis with a digital level.

2. Select "Zero Tilt Sensor" from the menu and press

the Brake Release button.

3. The current tilt sensor readings are displayed. To

zero both the X and Y direction sensor setting to the
machines’ present resting surface, press the Brake
Release button.

4. Select "Back to Main Menu" and press the Brake

Release Button.

5. Power machine off and begin operation.

Operator Programming Mode - (Level-3)

In the Operator Programming Mode the following items
are shown on the main menu (Also See Table 4-1 on Page
4-13)
:

• Tilt Sensor
• Program

NOTE: There are two production modules available, one for

North/South American and European languages,
and one for Asian languages. All programmable
items between these modules are identical with the
exception of language selection.

Tilt Sensor

Allows viewing current tilt sensor individual X and Y direc-
tion degree reading.

Program

Allows the Operator to program Level-3 items shown in
Table 4-1 on Page 4-13.