2

Mode Select Delay (Active before timeout)

5 SEC.

1 - 60 SECONDS

2

Acceleration (Platform Lowered)

80

1 - 100

2

Deceleration (Platform Lowered)

90

1 - 100

2

Turn Acceleration (Platform Lowered)

80

1 - 100

2

Turn Deceleration (Platform Lowered)

100

1 - 100

2

Maximum Forward Speed (Platform Lowered)

100

1 - 100

2

Minimum Forward Speed (Platform Lowered)

40

1 - 100

2

Maximum Reverse Speed (Platform Lowered)

50

1 - 100

2

Minimum Reverse Speed (Platform Lowered)

20

1 - 100

2

Maximum Turn Speed (Platform Lowered)

30

1 - 100

2

Minimum Turn Speed (Platform Lowered)

15

1 - 100

2

Minimum Forward Speed (Platform Elevated)

13

1 - 100

2

Minimum Reverse Speed (Platform Elevated)

9

1 - 100

2

Minimum Turn Speed (Platform Elevated)

5

1 - 100

2

Motor Compensation

50 mOhms

0 - 500 mOhms

Table 4-1. Ground Control Module - Field Programmable Settings and Factory Preset. (10MSP)

Level-2: Service Level Settings On LCD Display: YES =

HIGH =

Level-3: Operator Level Settings NO =

L OW =

LEVEL

PROGRAMMABLE ITEM

FACTORY

PRESET

SETTING RANGE

Advertising