2
Mode Select Delay (Active before timeout)
5 SEC.
1 - 60 SECONDS
2
Acceleration (Platform Lowered)
80
1 - 100
2
Deceleration (Platform Lowered)
90
1 - 100
2
Turn Acceleration (Platform Lowered)
80
1 - 100
2
Turn Deceleration (Platform Lowered)
100
1 - 100
2
Maximum Forward Speed (Platform Lowered)
100
1 - 100
2
Minimum Forward Speed (Platform Lowered)
40
1 - 100
2
Maximum Reverse Speed (Platform Lowered)
50
1 - 100
2
Minimum Reverse Speed (Platform Lowered)
20
1 - 100
2
Maximum Turn Speed (Platform Lowered)
30
1 - 100
2
Minimum Turn Speed (Platform Lowered)
15
1 - 100
2
Minimum Forward Speed (Platform Elevated)
13
1 - 100
2
Minimum Reverse Speed (Platform Elevated)
9
1 - 100
2
Minimum Turn Speed (Platform Elevated)
5
1 - 100
2
Motor Compensation
50 mOhms
0 - 500 mOhms
Table 4-1. Ground Control Module - Field Programmable Settings and Factory Preset. (10MSP)
Level-2: Service Level Settings On LCD Display: YES =
HIGH =
↑
Level-3: Operator Level Settings NO =
L OW =
↓
LEVEL
PROGRAMMABLE ITEM
FACTORY
PRESET
SETTING RANGE