Machine Drives in Opposite Direction

Table 6-46. Machine Drive in Opposite Direction

STEP

ACTION

SPEC

YES

NO

1.

At the Traction Control Module, check if the left drive motor power lead is
plugged into the M1 socket.

Go to Step 2

Switch the Left and

Right Drive Motor

Power Leads at the

Traction Module

2.

Remove the Right Drive Motor power lead at the Traction Control Module
(M2) and check if the WHITE wire is connected to the positive (+) terminal
and the BLACK wire is connected to the negative (–) terminal. (Reference
Figure 6-7., Electrical Diagram

Go to Step 3

Rewire as

Necessary

3.

Remove the Left Drive Motor power lead at the Traction Control Module
(M1) and check if the BLACK wire is connected to the positive (+) terminal
and the WHITE wire is connected to the negative (–) terminal. The Left
Motor Power lead is reversed from the Right Motor lead due to the reverser
harness. (Reference Figure 6-7., Electrical Diagram

Consult
Factory

Rewire as

Necessary