Component electrical connections -6 – JLG 10MSP Service Manual User Manual
Page 70
SECTION 4 - CONTROL COMPONENTS
4-6
– JLG Lift –
3121228
Figure 4-2. Component Electrical Connections.
1. Ground Control Module (a)
4. Right Side Battery (b)
7. Power Cable To Right Drive Motor/Brake (a)
2. Left Side Battery (b) (c)
5. Traction Control Module (a)
8. Hydraulic Pump/Motor/Tank Assembly (b)
3. 175 Amp Fuse
6. Power Cable To Left Drive Motor/Brake (a)
Ground Control
P1 - Horn, Alarm, Beacons, Lift Down Valve Harness (a)
P4 - Platform Joystick Harness (a)
Module Plugs:
P2 - Elevation/Speed, Charger Limit Switch Harness (a)
P5 - Joystick Protocol Harness to
P3 - Programmable Security Lock Harness (Option) (a)
Traction Control Module (a)
Notes:
(a) Apply di-electric grease JLG Part Number 3020038 to wiring harness terminals, to prevent moisture from entering module.
(b) Seal NEG (–) and POS (+) posts with battery grease to prevent corrosion.
(c) An quick-disconnect is installed on the left battery (+) POSITIVE cable for easier power disconnect when servicing machine.