1.1 CAPACITIES

System Voltage

24 Volt DC

Hydraulic System

5 qts. U.S. (4.7 L)

Drive Motor GearBox (Gear Oil)

10 oz. (296cc)

1.2 COMPONENT DATA

Hydraulic Pump/Pump Motor Assembly

Pump Motor - 24 Volt DC motor, Standard Duty

Pump Displacement - .098 cu. in./rev. (1.6cc/rev.)

Pump Output (Max.) - 2.25 gpm @ 1400 psi @ 24 volts
and 105 amps @ 43 centistrokes (200 SSU)

Reservoir Capacity - 1 Gallon (3.78 L)

Rear Wheel Drive Motors

Drive Motors - 24 Volt DC, Variable

Gear Box - 3500 in.lb. (395.5 Nm) - Continuous Output

7000 in.lb. (791 Nm) - Intermittent Output
30.68:1 Gear Ratio

Brakes -

Friction Disk - Spring Applied - Electrically
Released

Batteries/Battery Charger

Batteries - 12 Volt DC (2 in series @ 24 volt)

6 Volt DC (4 in series @ 24 volt)

Nominal Capacity - 12V - 100 Amp Hour @ 20 Hr.

6V - 210 Amp Hour @ 20 Hr.

Type - M2 Marine Combination (AGM)/Valve Regulated/

Leak Proof/NonCorrosive/Maintenance Free

Weight -12V - 65.7 lb. (29.8 Kg) - Per Battery

6V - 64 lb. (29 Kg) - Per Battery

JLG MACHINES EQUIPPED WITH DELTA Q BATTERY CHARGERS
ARE DESIGNED FOR THE BEST PERFORMANCE WITH OEM FAC-
TORY APPROVED BATTERIES.
APPROVED JLG REPLACEMENT BATTERIES ARE AVAILABLE
THROUGH JLG' S AFTERMARKET PARTS DISTRIBUTION CEN-
TERS OR JLG' S AFTERMARKET PROGRAMS. FOR ASSISTANCE
WITH PROPER BATTERY REPLACEMENT, PLEASE CONTACT
YOUR LOCAL JLG SUPPORT OFFICE.
BATTERIES APPROVED BY JLG HAVE BEEN TESTED FOR COM-
PATIBILITY WITH THE ALGORITHM PROGRAMMING OF THE
DELTA Q BATTERY CHARGER TO OPTIMIZE BATTERY LIFE AND
MACHINE CYCLE TIMES. THE USE OF NON APPROVED BATTER-

IES IN YOUR JLG EQUIPMENT MAY RESULT IN PERFORMANCE
ISSUES OR BATTERY CHARGER FAULT CODES. JLG ASSUMES
NO RESPONSIBILITY FOR SERVICE OR PERFORMANCE ISSUES
ARISING FROM THE USE OF NON APPROVED BATTERIES.

Battery Charger -

Microprocessor Controlled/SCR Circuit Monitor
120/240 Volt A.C. Selectable / 50/60 Hz input
24 volt, 20 amp output - with 2 amp finish
Reset Circuit Breaker
Automatic Charge Circuit
Plug Interlock Circuit

NOTE: The 10MSP batteries require approximately five (5)

hours to fully charge when drained to 80% discharge
- (Only the RED LEDS on platform console lit).

1.3 PERFORMANCE DATA

Platform Capacity

NOTE: Distribute weight evenly in platform and material tray

when loading. Reference the capacity decal located
on the machines mast cover in the operators plat-
form.

Maximum Horizontal Manual Side Force

(Platform fully extended with Maximum load)

ANSI/CSA:

100 Lb. (445 N)

CE/AUST/JPN:

45 Lb. (200 N)

Platform Size

23 in.-W x 19.5 in.-L (58cm) x (49cm)

Material Tray Size

28.75 in.-W x 25.68 in.-L (73cm) x (65cm)

Platform Height - (Fully Elevated)

10 ft. (3.05m) - Standard (To floor of platform)
7 ft. (2.13m) - with Height Limiter (To floor of platform)

Platform Maximum (Working) Height

(Platform fully elevated + Operator height)

16 ft. (4.92m) approximately

Table 1-2. Platform Maximum Capacity

SPECIFICATION

MAXIMUM CAPACITY

MAX. WIND

SPEED

Platform

Load

Material

Tray Load

Carry

Deck

ANSI/CSA

350 lb.

(160kg)

250 lb.

(115kg)

250 lb.

(115kg)

28 mph

(12 m/s)

CE

(Indoor Use Only)

0 m/s

Australia

(Indoor Use Only)

0 m/s

Advertising