Cover Removal/Installation
THE MAIN CIRCUIT BOARD AND THE SMALLER LCD CIRCUIT
BOARD MOUNTED TO THE COVER ASSEMBLY, ARE CON-
NECTED BY A RIBBON CABLE. REMOVE THE COVER CARE-
FULLY ONCE THE COVER SCREWS ARE REMOVED FROM THE
BACK OF THE MODULE.
Cover Installation
1. Remove the (6) Hex Socket Screws from the Heat Sink/
Base. One screw is under the Warranty/Tamper Label.
Disconnect the Ribbon Cable
1. Ribbon Cable Connector
3. Support for Cover
2. Ribbon Cable
1
1
2
3
Release Ribbon Cable
1. Ribbon Cable Connector Tabs
(Push tabs away from connector to release
cable then slide cable out of connector)
Note: Connector works same at both ends of the ribbon cable.
Reconnecting Ribbon Cable
1. Ribbon Cable Connector Release Tabs
(Slide cable into connector then push tabs
back into connector)
Note: Connector same at both ends of the ribbon cable.