CHAMPION DH5000T Single Source Gas Manual User Manual

Page 103

Advertising
background image

95

P/N 115107 - Condensate Removal Option Installation Instructions

Condensate Removal Shroud Electrical and Plumbing Connections

The following pages describe the electrical fan connection and the plumbing connections for the

Condensate Removal Option. The chemical injection points for the Tall Hood-type Series are also

included.

(A) Preconnected hose to the

inlet of the vacuum breaker.

The other end of this hose

is connected to the booster

outlet.

(B) Preconnected hose to the

outlet of the condensate coil.

The other end of this hose

is connected to the inlet of the

line strainer.

(C) Preconnected hose to the

outlet of the vacuum breaker.

The other end of this hose

is connected to the inlet final

rinse piping located behind the

hood spring on the right-hand

side of the hood as viewed

from the rear.

(D) Cold water supply inlet.

(E) Condensate vent fan wires.

(F) Final rinse-aid injection point.

(G) Main power supply wire

mounting bracket.

(H) Detergent injector and sensor

connection points.

(continued on next page)

H

B

C

D

E

F

G

A

B

A

Condensate

Removal

Shroud

Assembly

Advertising