Installation

Electrical Connections

WARNING

:

Electrocution or serious injury may result when working on an

energized circuit.
Disconnect power at the main breaker or service disconnect

switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is being

performed on the circuit.

! ATTENTION !

A qualified electrician must connect the main incoming power to the dishwasher in accordance

with all local codes and regulations or in the absence of local codes in accordance with the

National Electrical Code or the Canadian Electrical Code. Improper installation will not be

covered by the Limited Warranty.

1. Make sure the incoming power is disconnected

at the main disconnect switch or circuit breaker.

2. The dishwasher is available for either single or

three phase operation. Standard voltages are

208-240V/60/1 & 3, and 460-480V/60/3.

3. A Machine Electrical Connection Data Plate is

located directly below the input terminal block.

Make sure the incoming power supply matches

the machine's electrical requirement before

connecting incoming power.

4. Remove the front and left side dishwasher

panels.

5. The incoming power supply is routed from the

rear of the machine to the input terminal block

located at the front of the machine.

(See A and B on next page).

6. Connect the incoming power flexible conduit to

the incoming conduit mounting bracket

located on the rear of the dishwasher base

making sure to leave 6 feet [2 m] of excess

conduit and conductors to allow for servicing of

the dishwasher.

Connecting Incoming Power Supply

continued on next page

Incoming Power Routing.

8¾"

[222]

Power Bracket

and Conduit