P/N 115109 - Direct Vent Option Installation Instructions

Installing a Direct Vent Fan (Supplied By Others)

! VERY IMPORTANT !

The direct vent fan must not exhaust into a wall, ceiling, crawl space, or any other concealed space

of a building nor a gas vent or any other common vent.

The direct vent fan must exhaust to the outside of the building.

1. The exhaust vent fan supplied by others

must supply 250 CFM at 1/4" S.P.

suitable for installation as part of the

direct vent option.

2. Duct work, duct reducer associated

fasteners, and connectors must be

supplied by others.

3. The installation of a 6" to 4" duct

reducer is highly recommended as

shown in Figure A at left.

4. The length of duct and the location

of the vent fan must conform to

local codes and regulations.

! ATTENTION !

The vent installation must be performed by qualified

personnel in accordance with all local codes and regulations.

The direct vent option requires an exhaust vent fan capable of supplying 250CFM at 1/4" S.P.

at the dishwasher. Refer to Figure A below for the recommended configuration of the vent

duct at the dishwasher.

Direct Vent Shroud

Duct Reducer

(by others)

Vent Duct

(by others)

To

Vent Fan

(by others)