CHAMPION DH5000T Single Source Gas Manual User Manual

Page 87

Advertising
background image

2-3/8"

[60]

4"

[102]

I.D.

13"

[330]

Machine

Mounted

Direct

Vent Fan

Control Box

79

P/N 115109 - Direct Vent Option Installation Instructions

Tall Hood-type Series Direct Vent Option Description

93 14

[2369]

"

70 18

[1781]

Machine

Height

Direct Vent

Mounted

"

23

[584]

"

~

~

Direct Vent

A

B

The direct vent option is a stainless steel vent shroud (approximate weight 26 lbs/22 kg) and

a 120VAC/60/1 vent fan supplied by the factory or an alternate fan supplied by others. The

electrical connections for the vent fan are located in the direct vent electrical control box.

1. The direct vent shroud is mounted on

the top rear of the dishwasher using (4)

1/4-20 x 1/2" SST truss head screws.

(See Figure A).

2. The direct vent shroud must be

installed before the dishwasher

is permanently placed and before

connecting the utilities.

3. The installation of the direct vent fan

and duct work should be installed by

qualified personnel.

4. The dishwasher vent connection is a

round 4"[102mm] I.D. duct fitting.

5. The vent system must supply

250 CFM at 1/4" static pressure.

6. The dishwasher should be positioned

in a manner which allows the dish tables

and the machine to align for the proper

loading and unloading of the dish racks.

(See Figure B).

! VERY IMPORTANT !

The direct vent shroud must be installed before the dishwasher is permanently placed

and before the utilities are connected.

A DIRECT VENT FAN MUST BE INSTALLED TO EXHAUST AIR TO THE OUTSIDE.