Vanguard gas booster installation – CHAMPION DH5000T Single Source Gas Manual User Manual

Page 112

Advertising
background image

104

Gas Booster Heater Overview

UTILITIES

(Vanguard Installation Only)

1

ELECTRICAL

2

HOT WATER

3

2" O. D. MACHINE DRAIN CONNECTION

DRAIN

3/4" NPT HOT WATER 140°F FOR 40°F RISE
INLET WATER TO BOOSTER - MIN. 40PSI, MAX 80PSI

15 GPM MAX FLOW

4

GAS

CONNECTION

NATURAL GAS 199,100 BtuH

3/4" NPT

NATURAL GAS PRESSURE 10.5" MAX AT INLET

B BSTR CONNECTION 120V 1PH 6.2 AMPS

5

EXHAUST

CONNECTION

4" DIAMETER VENT DUCT WITH UNATTACHED

FLEXIBLE DUCTING. VENT PER LOCAL CODE

Vanguard Gas Booster Installation

NOTE:

The installation of your GAS BOOSTER must be performed by qualified service personnel.

Problems due to improper installation are not covered by the Warranty.

NOTE:

The installation of the GAS BOOSTER must comply with all local electrical, plumbing, health and

safety codes or in the absence of local codes, installed in accordance with the applicable

requirements of the Standard for Ventilation Control and Fire Protection of Commercial Cooking

Operations, NFPA 96.

NOTE:

Installation of the GAS BOOSTER must be in accordance

with local codes,or in the absence of local codes, with the

latest edition of the National Fuel Gas Code, ANSI Z223.1,

the National Electrical Code, ANSI/NFPA 70. Canadian

installations should conform with CSAB149.1, Natural Gas

and Propane Installation Code, and CSA-C22.1 Electrical

Code, and/or local installation codes.

{Les installations canadiennes doivent se conformer aux

CODES D’INSTALLATION CSA-B149.1, Natural Gas and

Propane Installation Code, et CSA-C22.1 Electrical Code,

et/ou aux codes locaux d’installation.}

NOTE:

The illustration below shows a typical straight-through

dishwasher installation with gas booster heater. Your

installation may be different. Refer to the installation

instructions shipped with your gas booster for details.

Typical Straight-through Dishwasher Installation

70 18

[1780]

29 34

[757]

27

[686]

CLEARANCE

19 58

[500]

8

[203]

CLEARANCE PER

VANGUARD

16

[406]

4

[102]

512

[140]

4

[102]

512

[140]

10 14

[260]

3

2

4

4

1B

2

5

"

"

"

"

"

"

"

"

"

"

"

FLOOR

Vanguard Technology Inc.

1(800) 624-4809

Advertising