P/N 115109 - Direct Vent Option Installation Instructions

Electrical Connections for the Optional Direct Vent Fan

(Supplied By The Factory)

Factory Vent Fan Terminal Block

120VAC/50-60/1

Terminal

Block

L

Factory Supplied Vent Fan Terminal Block

Wiring Diagram

M

! IMPORTANT !

Electrical installation must be performed by

qualified personnel in accordance with

all local codes and regulations or in the absence

of local codes then the National Electrical Code.

DO NOT CONNECT POWER

UNTIL THE FAN IS COMPLETELY INSTALLED.

1. The factory supplied vent fan is

120VAC/50-60/1.

2. Incoming power is connected to the vent

fan terminal block located in the vent

fan junction box on the side of the vent

fan assembly. (See Figure L).

3. Grounding of the vent fan is not

required because the fan motor is

isolated within the vent fan plastic

housing.

4. Connect the 120VAC power supply

to the vent fan terminal block.

(See Figure M).

5. If the 12 ft. [3.7 m] vent fan cable

supplied with the direct vent fan

control box is not long enough for the

installation, the installer may replace

the cable with a longer cord of the

same electrical specifications.

6. Refer to Figure N on the next

page for the direct vent fan control box

cable wiring diagram.

WARNING

:

Electrocution or serious injury may result when working

on an energized circuit.
Disconnect power at the main breaker or service

disconnect switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is

being performed on the circuit.