1. Connect the incoming power flexible conduit to the incoming conduit mounting bracket

located on the rear of the dishwasher base making sure to leave 6 feet [2 m] of excess

conduit and conductors to allow for servicing of the dishwasher.

2. Route the power conductors through the 1-1/2" rigid PVC Power Cable Conduit to the

front of the dishwasher as shown. (See A and B below).

3. Two cable tie mounts are provided on the base of the machine to secure the conductors.

Make sure the conductors do not block the front of the booster tank, (if equipped), so the

booster can be serviced easily.

4. Refer to the terminal block connection diagrams below and connect the incoming

power to the input terminal block as indicated according to the machine's power

requirements. (See C and D below).

5. CHECK MOTOR ROTATION FOR 208-240/460-480V/60/3 ONLY

. Check the rotation

direction of the wash pump motor according to the indicator arrow on the motor end cover

and reverse L1 and L2 at the input terminal block if the motor rotation is incorrect.

Installation

Electrical Connections

Connecting Incoming Power Supply

(continued)

SINGLE PHASE

POWER CONNECTION

208-240V/60/1

LINE IN

GND

NOT

USED

L1

L2

L3

L1

L2

THREE PHASE

POWER CONNECTION

208-240/440-480V/60/3

GND

LINE IN

L1

L2

L3

L1

L2

L3

D

C

Power Cable Bracket

Power Cable Conduit

A

B