CHAMPION DH5000T Single Source Gas Manual User Manual

Page 107

Advertising
background image

99

P/N 115107 - Condensate Removal Option Installation Instructions

Utility Connections for the Tall Hood-type Series

with Condensate Removal Option

Electrical Connections

WARNING

:

Electrocution or serious injury may result when working on an

energized circuit.
Disconnect power at the main breaker or service disconnect

switch before working on the circuit.
Lock-out and tag the breaker to indicate that work is being

performed on the circuit.

! ATTENTION !

A qualified electrician must connect the main incoming power to the dishwasher in accordance

with all local codes and regulations or in the absence of local codes in accordance with the

National Electrical Code. Improper installation will not be covered by the Limited Warranty.

Power Bracket

and Conduit

8-3/4"

[222]

F

Incoming Power Routing.

1. Make sure the incoming power is disconnected at

the main disconnect switch or circuit breaker.

2. The dishwasher is available for either single or

three phase operation. Standard voltages are

208-240V/60/1 & 3, and 460-480V/60/3.

3. A Machine Electrical Connection Data Plate is

located directly below the input terminal block.

Make sure the incoming power supply matches

the machine's electrical requirement before

connecting incoming power.

4. Remove the front and left side dishwasher panels.
5. The incoming power supply is routed from the

rear of the machine to the input terminal block

located at the front of the machine.

Connecting Incoming Power Supply