Ac l – CHAMPION DH5000T Single Source Gas Manual User Manual

Page 85

Advertising
background image

77

Temperature Display Adjustment - (For Service Technicians Only)

Temperature Display Adjustment - For Service Technicians Only

(continued)

7. If the temperature displays display "EEE" this indicates that the thermistor plug was not

disconnected. STOP and review steps 1-5 above.

8. Push and hold the CHECK button and the RESET at the same time.
9. Release the RESET button.
10. Release the CHECK button. Both displays flash "CAL"; the semi-circular bars are blank.

11. Push and hold the TEST A button. The wash display should indicate "160".
12. Release the TEST A button. The wash display should indicate "E".
13. Push the RESET button to complete the verification of the wash display.
14. Repeat steps 8-10 and then push and hold the TEST B button.

The rinse display should indicate "160".

15. Release the TEST B button. The rinse display should indicate "E".
16. Push the RESET button to complete the verification of the rinse display.

17. The verification procedures are complete.
18. Turn the dishwasher power switch OFF, turn the main disconnect circuit breaker off,

reconnect the thermistor plug and the rinse switch connector wire.

19. Replace the front panel and return the dishwasher to normal operation.

Verifying the Alphanumeric Display

(continued)

A

C L

"CAL" indicates the temperature display

board is verifying its internal operation.

E

"E" after "CAL" is displayed to indicate

the verification is complete.

Advertising