98

P/N 115107 - Condensate Removal Option Installation Instructions

Utility Connections for the Tall Hood-type Series

with Condensate Removal Option

Plumbing Connections

! VERY IMPORTANT !

The incoming cold water supply pressure must be a minimum

of 45 PSI flowing pressure measured at the cold water supply connection.

1. The dishwasher equipped with a Condensate Removal Option requires an incoming cold

water supply only (See Figure E below).

COLD WATER — 3/4" NPT, 55-75°F/13-24°C Maximum temperature, with a minimum

incoming flowing pressure of 45 PSI measured at the dishwasher supply connection

before adjusting operating pressure to 20/25 PSI flowing pressure.

2. A water hardness of 3 grains/gal (US) [51.3 mg/L] or less is recommended.

The cold water supply connection is located on the left side of the dishwasher

approximately 64" above the finished floor (see the illustration below).

3. A manual shut-off valve, 3/4" or larger, should be installed in the cold water supply line

as close to the dishwasher as possible for servicing.

E

3/4" NPT

Cold water

supply connection

Detail View

64"

[1626]