The Direct Vent Fan Electrical Control Box is shipped

prewired to the dishwasher and stowed in the left rear

corner of the machine. Mounting holes and fasteners

are provided to mount the control box on the left side

of the machine. A 12 ft. [3.7m] vent fan cable is

prewired to the control box. (See Figure G).

To Install the Electrical Control Box:

P/N 115109 - Direct Vent Option Installation Instructions

Installing the Direct Vent Fan Electrical Control Box on the left-hand side

of the Tall Hood-type Series dishwasher.

1. The electrical control box must be installed

before the dishwasher is permanently

placed and before the dishwasher tables

are connected to the dishwasher.

2. Refer to Figure G at right. The photo

shows the electrical control box mounted

on the left side of the dishwasher

approximately 46" [1.2 m] above the

finished floor.

3. Note the 12 ft. [3.7 m] vent fan power

cable for the Factory supplied vent fan

has been prewired to the control box.

This cable is provided to connect 120VAC

power to the vent fan.

4. Refer to Figure H at right. The photo

shows the storage location for the

electrical control box during shipping.

5. Carefully lift the control box and mounting

bracket assembly from the rear of the

dishwasher and place it on the floor on

the left-hand side of the machine.

G

CONTROL

BOX

VENT FAN

CABLE

H

CONTROL

BOX

! ATTENTION !

The Direct Vent Fan Control box can be wall-mounted using a Wall Mount Kit, P/N 900958.

See the last page of this manual for further instructions.