Description – Det-Tronics U9500 Infiniti Gas Transmitter User Manual

Page 5

Advertising
background image

95-8444

3

10.1

DESCRIPTION

The U9500 is a single channel gas detection device. In

addition to the standard 4-20 mA analog signal output,

the U9500 offers 4 optional relay outputs for fault and

alarm indications. The 4 outputs are: fault, high alarm,

low alarm, and auxiliary alarm. The relays have form C

(SPDT) contacts. Low, auxiliary and high alarm relay

contacts are selectable as a group for latching or non-

latching operation. During normal operation, the fault

relay is non-latching, but for initialization faults, the fault

relay latches. The alarm relays are also selectable, as a

group, for normally energized or de-energized with no

alarms. The fault relay is always normally energized for

no fault.

NOTE

Since the relays can be programmed to be either
energized or de-energized on alarms, the term
“actuate” is used to indicate that the output is in an
alarm condition.

The U9500 provides an eight character, single line, alpha-

numeric LCD display. The U9500 has four switches

located on the display. The visible three switches are

single pole, normally open push buttons, and are

designated as: Setup\accept, increase, and decrease.

The fourth switch is a magnetic reed switch, designated

cal/reset, which is used by the customer for non-intrusive

calibrations and for resetting of the U9500.

Two additional options are available for resetting the

transmitter. A user supplied switch can be wired to the

transmitter terminal block and used to reset the device

from a remote location.

In addition, Detector Electronics offers a special optional

enclosure with a pushbutton pre-installed within a multi-

port electrical enclosure for customers who do not prefer

magnetic switches.

The U9500 is compatible with the entire Detector

Electronics sensor family. In some cases, special

personality cards are required to ensure proper

operation with a specific sensor, including the Det-

Tronics Combustible Gas sensors. The proper U9500

model must be ordered by the customer to ensure

proper operation and markings for the desired sensor

type. Refer to Appendix C for combustible gas sensor

ATEX/CE ratings and installation details. Refer to form

90-1041 for specification details.

Modes of operation

The U9500 has three main operating modes:

Normal

Calibrate

Setup (also called Configuration).

Normal mode is the default mode, no buttons pushed.

Three minor modes also exist:

Setpoint display

Reset

Power up.

3.46

(8.8)

NOTE: TO MOUNT THE TRANSMITTER, DRILL 5/6" (7.9375mm) HOLES
AND USE 1/4" (6.35mm) BOLTS.

4.7

(11.9)

2.7

(6.9)

5.2

(13.2)

5.86

(14.9)

6.57

(16.7)

1.28

(3.3)

B2307

Figure 1—Infiniti Transmitter Dimensions in Inches (Centimeters)

Advertising