Basic safety instructions

12

13

Basic safety instructions

This user‘s manual and all safety instructions must be observed, read

and understood by all personnel working on the fixture (in particular in

reference to the safety instructions).

Responsibilities of the operating personnel

Verify that the distillation material can be evaporated safely and that the distillation

residue is not explosive.

Verify that work using an open flame is not conducted in the surroundings of the

rotary evaporator (explosion risk).

Verify that the flow rate of < 1 m/s is guaranteed when suctioning liquids that contain

combustible materials (electrostatic charge; ignition risk).

Verify that gases of explosion group IIC do not occur in materials or chemical

reactions, such as hydrogen.

Verify that equipment that is an emission or radiation source (electromagnetic waves)

for the frequency range (3*1011Hz to 3*1015Hz) is not operated or attached.

Verify that equipment that is an emission or radiation source for ionizing waves or

that is within the ultrasound range is not operated or attached.

Verify that adiabatic compression and shock waves do not occur (shock wave

ignition).

Verify that the use of substances with the risk of an uncontrolled release of energy

associated with a rise in pressure is prohibited (exothermic reaction; self-ignition of

dust).

Verify that the glass surfaces are wiped off by using only damp cloths.

Wear suitable protective clothing for activities on the rotary evaporator a (with gog-

gles and gloves, if necessary).

Avoid pressure on the LCD screen, it is not intended to be a touch screen interface.

Verify that the maximum excess pressure of the coolant equals no more than 1 bar in

the condenser.

Verify that the basic device is only plugged to or unplugged from the heating bath if

the main switch is switched off and/or the main power supply is disconnected.

Qualifications of Personnel

The target group of the rotary evaporator is qualified personnel only. The rotary evapora-

tor may only be used by personnel that have been trained in the proper operation by

qualified personnel determined in accordance with the internal safety regulations of the

facility in which the rotary evaporator is operated.

Safety Conscious Working

Heidolph Instruments is not liable for personal injuries and / or property damages caused

by an incorrect and improper usage of the rotary evaporator.

Observe the following regulations:

‒ Laboratory guidelines

‒ Accident prevention regulations

‒ Ordinance on Hazardous Substances

‒ Other generally accepted rules of safety engineering and occupational health

‒ Local regulations

Safety devices on the equipment

Heating bath

Electronic and mechanical excess temperature protection

Electronic temperature control

Base unit

Clamps to secure evaporation and receiving flasks

Adjustable immersion depth of the evaporator flask

The evaporator flask may be lifted from the heating bath, if required

Overcurrent protection on lift motors (only Hei-VAP Ad-vantage and

Hei-VAP Precision)

Thermal over temperature protection on the drive motor

Torque restrictor

Glassware set

Borosilicate glass

Screw connectors on the connections

Support rod and clamp for glassware sets G3, G5 and G6

Optional

Surlyn coating (Safecoat coating for glassware set G5) of the glassware parts

Protective hood